Fluke 17B MAX Digital Multimeter
SKU:
Fluke-17B-Max
Key features
- Audible and visual alarm for incorrect connections
- Test leads with fines tips for circuit board testing
- Simple interface to wake meter from sleep mode by activating any buttons
- Voltage: 6000-count reading
- Capacitance range: 2000uF
- Safety rating: CATIII 600V
- Frequency and temperature measurement
₨43,500.00
19
People watching this product now!
Payment Methods:
Description
Specifications: Fluke 17B MAX Digital Multimeter
| Specifications | ||||
|---|---|---|---|---|
| Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 % Accuracy specifications take the form of: ± ([% of Reading] + [Number of Least Significant Digits]). | ||||
| Function | Range | Resolution | Accuracy | |
| 15B MAX | 17B MAX | |||
| AC Volts (40 Hz to 500 Hz)1 | 6.000 V 60.00 V 600.0 V 1000 V |
0.001 V 0.01 V 0.1 V 1 V |
1.0 % + 3 | 1.0 % + 3 |
| AC Millivolts | 600.0 mV | 0.1 mV | 3.0 % + 3 | 3.0 % + 3 |
| DC Volts | 6.000 V 60.00 V 600.0 V 1000 V |
0.001 V 0.01 V 0.1 V 1 V |
0.5 % + 3 | 0.5 % + 3 |
| DC Millivolts | 600.0 mV | 0.1 mV | 1.0 % + 10 | 1.0 % + 10 |
| AC Current μA (40 Hz to 400 Hz)2 | 400.0 μA 4000 μA |
0.1 μA 1 μA |
1.5 % + 3 | 1.5 % + 3 |
| AC Current mA (40 Hz to 400 Hz)2 | 40.00 mA 400.0 mA |
0.01 mA 0.1 mA |
1.5 % + 3 | 1.5 % + 3 |
| AC Current A (40 Hz to 400 Hz)2 | 4.000 A 10.00 A |
0.001 A 0.01 A |
1.5 % + 3 | 1.5 % + 3 |
| DC Current μA2 | 400.0 μA 4000 μA |
0.1 μA 1 μA |
1.5 % + 3 | 1.5 % + 3 |
| DC Current mA2 | 40.00 mA 400.0 mA |
0.01 mA 0.1 mA |
1.5 % + 3 | 1.5 % + 3 |
| DC Current A2 | 4.000 A 10.00 A |
0.001 A 0.01 A |
1.5 % + 3 | 1.5 % + 3 |
| Diode Test3 | 2.000 V | 0.001 V | 10% | 10% |
| Temperature 4 | 50.0 °C to 400.0 °C 0 °C to 50.0 °C -55.0 °C to 0 °C |
0.1 °C | NA | 2 %+1 °C 2 °C 9 %+2 °C |
| Resistance (Ohms)5 | 400.0 Ω 4.000 kΩ 40.00 kΩ 400.0 kΩ 4.000 MΩ 40.00 MΩ |
0.1 Ω 0.001 kΩ 0.01 kΩ 0.1 kΩ 0.001 MΩ 0.01 MΩ |
0.5 % + 3 0.5 % + 2 0.5 % + 2 0.5 % + 2 0.5 % + 2 1.5 % + 3 |
0.5 % + 3 0.5 % + 2 0.5 % + 2 0.5 % + 2 0.5 % + 2 1.5 % + 3 |
| Capacitance6 | 40.00 nF 400.0 nF 4.000 μF 40.00 μF 400.0 μF 2000 μF |
0.01 nF 0.1 nF 0.001 μF 0.01 μF 0.1 μF 1 μF |
2 % + 5 2 % + 5 5 % + 5 5 % + 5 5 % + 5 5 % + 5 |
2 % + 5 2 % + 5 5 % + 5 5 % + 5 5 % + 5 5 % + 5 |
| Frequency1Â (10 Hz to 100 kHz) | 50.00 Hz 500.0 Hz 5.000 kHz 50.00 kHz 100.0 kHz |
0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 kHz |
NA | 0.1 % + 3 |
| Duty Cycle1 | 1% to 99% | 0.10% | NA | 1 % typical7 |
| Continuity Threshold | — | — | 70Ω | 70Ω |
| Backlight | — | — | Yes | Yes |
| 1 All ac, Hz, and duty cycle are specified from 1 % to 100 % of range. Inputs below 1 % of range are not specified. 2 Typical burden voltage: DC/AC Current µA: 100 µV / µA; DC/AC Current mA: 2 mV/mA; DC/AC Current A: 0.03 V/A 3Typically, open circuit test voltage is 2.0 V and short circuit current is <0.6 mA 4Use Type K thermocouple 5 Typical open circuit test voltage is 0.54 V, maximum short circuit current is 1.8 mA 6Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 40 nF range). 7 Typical means when the frequency is at 50 Hz or 60 Hz and the duty cycle is between 10 % and 90 %. |
||||
| Input Characteristics | ||||
|---|---|---|---|---|
| Function | Overload Protection | Input Impedance (Nominal) | Common Mode Rejection Ratio | Normal Mode Rejection Ratio |
| AC Volts | 1000 V 1 | >10 MΩ, <100 pF | >60 dB at 50 Hz or 60 Hz | — |
| AC Millivolts | 1000 V 1 | >1 MΩ, <100 pF | >80 dB at 50 Hz or 60 Hz | — |
| DC Volts | 1000 V 1 | >10 MΩ, <100 pF | >100 dB at 50 Hz or 60 Hz | >60 dB at 50 Hz or 60 Hz |
| DC Millivolts | 1000 V 1 | >1 MΩ, <100 pF | >80 dB at 50 Hz or 60 Hz | — |
| 1106Â V Hz max | ||||
| General Specifications | |
| Maximum voltage between any Terminal and Earth Ground | 600 V |
| Maximum differential voltage between V and COM terminals | 1000V |
| Display (LCD) | 6000 counts, updates 3/sec |
| Battery Type | 2 AA, IEC LR6 |
| Battery life | 500 hours minimum |
| Temperature | Operating 0 °C to 40 °C; Storage -30 °C to 60 °C |
| Relative Humidity | Operating Humidity Non-condensing (<10 °C); ≤90 % RH at 10 °C to 30 °C; ≤75 % RH at 30 °C to 40 °C |
| Operating Humidity, 40 MΩ range | ≤80 % RH at 10 °C to 30 °C; ≤70 % RH at 30 °C to 40 °C |
| Altitude | Operating 2000 m; Storage 12000 m |
| Temperature Coefficient | 0.1 X (specified accuracy) /°C (<18 °C or >28 °C) |
| Fuse protection for current inputs | 440 mA, 1000 V, fast-blow, use only Fluke specified parts. 11 A, 1000 V, fast-blow, use only Fluke specified parts |
| Size (HxWxL) | 183 mm x 91 mm x 49.5 mm |
| Weight | 455 g |
| Ingress Protection | IP40 |
| Safety | IEC 61010-1, IEC61010-2-030: CAT III 600 V, Pollution Degree 2 |
Customer Reviews
Rated 0 out of 5
0 reviews
Rated 5 out of 5
0
Rated 4 out of 5
0
Rated 3 out of 5
0
Rated 2 out of 5
0
Rated 1 out of 5
0
Be the first to review “Fluke 17B MAX Digital Multimeter” Cancel reply
Related Products
MECHANIC Thor Power Adjustable DC Regulated Power Supply Expansion Interface Intelligent IoT Digital Diagnostic Power Supply
Rated 0 out of 5
In stock
₨29,000.00
SKU:
THOR POWER
FNIRSI S1 Large Screen Digital Display Smart Multimeter
Rated 0 out of 5
In stock
SKU:
S1
Kada 850 Hot Air Soldering Station SMD Rework Station Heat Gun
Rated 0 out of 5
In stock
₨4,650.00
SKU:
Kada 850
Zoyi ZT-102L Mini Auto Inductance 60 Henrys H Measurement Digital Multimeter
Rated 0 out of 5
In stock
₨4,000.00
SKU:
ZT-102L
FNIRSI DMC-100 DC AC Current Voltage Clamp Meter Digital Multimeter
Rated 0 out of 5
In stock
SKU:
DMC-100

Reviews
Clear filtersThere are no reviews yet.